One Stop Supplier Of Testing Instruments And Electric Tools

Sales & Support
Request A Quote - Email
Select Language
English
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPressure Manometer

TL-101 Digital LCD Display 5PSI Pressure Manometer

All Products
Hour Meter (35)
Certification
Good quality Air Qaulity Monitor for sales
Good quality Air Qaulity Monitor for sales
I'm Online Chat Now

TL-101 Digital LCD Display 5PSI Pressure Manometer

China TL-101 Digital LCD Display 5PSI Pressure Manometer supplier
TL-101 Digital LCD Display 5PSI Pressure Manometer supplier TL-101 Digital LCD Display 5PSI Pressure Manometer supplier TL-101 Digital LCD Display 5PSI Pressure Manometer supplier TL-101 Digital LCD Display 5PSI Pressure Manometer supplier

Large Image :  TL-101 Digital LCD Display 5PSI Pressure Manometer

Product Details:

Place of Origin: China
Certification: CE ,Rohs
Model Number: GS-TL101

Payment & Shipping Terms:

Minimum Order Quantity: 100pcs
Price: 22.8USD
Packaging Details: Color Box
Delivery Time: 3-5 days for sample order or according to your order quantity
Payment Terms: Paypal ,West Union,T/T, MoneyGram
Supply Ability: 10000 pcs/month
Contact Now
Detailed Product Description
Pressure Range: +5psi Accuracy: +0.3% FSO (at 25 ℃)
Repeatability: +0.2% (Max+0.5%FSO) Response Time: 0.5s Typical

Features:
 
 
* Single and different pressure measurement
* Calibration function
* Over Range Indicator
* Large LCD with backlight
* Data Hold and Error mode
* 11 Selectable units of Measure
* Max / Min/ Avg reading function
* Zeroing offset, and data compensation
* Low battery display and automatic shutdown
 
 
Specifications:
 
 
Pressure Range:+5psi
Accuracy:+0.3% FSO (at 25)
Repeatability: +0.2% (Max+0.5%FSO)
Linearity/Hysteresis:+0.29% FSO
Response Time:0.5s Typical
Over Range Indicator:Hi
Under Range Indicator:Lo
Operation temperature:0 to 50oC(32 to 122oF)
Operation humidity:10 to 90%RH
Storage temperature: -10 to 60oC(14 to 140oF)
1Storage humidity:10 to 75%RH
Size:160*55*35mm
Weight:150g(included 9V battery)
 

 

Function Range Resolution Function Range Resolution
kPa 34.47 0.01 inHg 10.18 0.01
Psi 5 0.001 mmHg 258.5 0.1
Kgfcm2 0.351 0.001 InH2O 138.3 0.1
Ozin2 80 0.01 FtH2O 11.53 0.01
Bar 0.344 0.001 cmH2O 351.5 0.1
Mbar 344.7 0.1      

 

Operation

 

1. Power on/off

 

Press Power on/off button to turn on or off..

The meter will auto power off in 10 minutes without any operation.

Press HOLD button and Power on/off button together to turn on the meter, the Power symbol will

Appear on the display. the meter won’t auto power off until the battery run out.

 

2. Data Hold Function

 

Press the HOLD button to freeze the reading momentarily.

Press the HOLD button again to return the normal mode

 

3. Record Function

 

When turn on the instrument, it already starts recording the MAX/MIN/AVG reading.

Press the REC button to display the max reading, min reading, average reading

 

4.Backlight

 

Press the HOLD/Backlight button over 2sec to turn on/off the backlight.

 

5. Unit Selection

 

Press the UNITS button to choose the suitable unit.

 

6.Over Range

 

HI symbol will appear on the display when the pressure value over the Max range

LO symbol will appear on the display when the pressure below the MIN range

 

7. Calibration

 

Hold REC and DIF button together and then turn on the instrument to enter the calibration method directly:

 

a. Zero adjustment

 

Press REC and DIF button at the same time, the reading will be -00.00.

 

b. Data Adjustment

 

Connect the pressure calibrator then input a standard pressure value (kPa),and then adjust the reading the same as the standard pressure value.

*REC button (←); DIF button (→); HOLD button (↑); UNITS button (↓)

 

Battery Replacement:

 

If the meter does not power on as usual or the low battery icon TL-101 Digital LCD Display 5PSI Pressure Manometer appears on the LCD display, please replace the batteries with a new 9V battery as soon as possible. The way to open the battery cover sees below operation:

 

Dispose of the battery in an environmentally safe at a recycling point.


DO NOT DISPOSE OF IN YOUR BIN!
 

Trouble Shooting:

 

1. Power on but no display or the display disappears

 

a. Check the battery is in place with good contact to the pins and the correct way round.

b. Remove battery for one minute and re-install.

c. Replace the battery.

 

2. For all other issues please contact us.

 

Warranty:

 

This meter has a one year warranty for a period of one year from date of purchase.

 

This warranty covers normal operation and does not cover batteries (including leaks), misuse, abuse, alteration, tampering, neglect, improper maintenance or improper calibration. Nor can the warranty be used as an excuse for a false claim simply because you have changed your mind after the initial 14 day period.

 

Proof of purchase is required for warranty repairs.

 

Contact Details
SHENZHEN G-SUN OPTOELECTRONICS CO.,LTD

Contact Person: Mr. Steven

Tel: 86-0755-33138807

Fax: 86-0755-33138807

Send your inquiry directly to us (0 / 3000)